10 common problems with coin-operated machines
1. Do not counted: COIN output and switch gear is incorrect, to adjust COIN time switch.
2. Less points: The outlet of adjusting COIN time switch is not smooth.
3. Multiple points: COIN time switch is faulty.
4. Do not smooth: To Adjust the precision switch of knob clockwise to normal. The sample coin is not clipped properly. Try another sample coin again.
5. Counterfeit money: To Adjust the knob precision switch counterclockwise to normal.
6. The blue light when the red light is off, but the coin is stuck: The sensitivity knob is too tight and the sample is not clipped properly. Try another sample coin.
7. The red light is on and the blue light is off: There may be debris in the coin path, stuck coin or electric eye damage.
8. The red light flashing and the blue light electric eye self-test error: There may be debris card coins or electric eyes.
9. Stuck coin: Open the side cover to remove blocked coins, remove dirt in the coin channel, and adjust the size of the panel metal sheet position to prevent large coins from being thrown in.